Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.787
Filtrar
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 179-183, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605618

RESUMO

Objective: To introduce a locating device for the entry point of intramedullary nail based on the inertial navigation technology, which utilizes multi-dimensional angle information to assist in rapid and accurate positioning of the ideal direction of femoral anterograde intramedullary nails' entry point, and to verify its clinical value through clinical tests. Methods: After matching the locating module with the developing board, which are the two components of the locating device, they were placed on the skin surface of the proximal femur of the affected side. Anteroposterior fluoroscopy was performed. The developing angle corresponding to the ideal direction of entry point was selected based on the X-ray image, and then the yaw angle of the locating module was reset to zero. After resetting, the locating module was combined with the surgical instrument to guide the insertion angle of the guide wire. The ideal direction of entry point was accurately located based on the angle guidance. By setting up an experimental group and a control group for clinical surgical operations, the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss with or without the locating device was recorded. Results: Compared to the control group, the experimental group showed significant improvement in the number of guide wire insertion times, surgical time, fluoroscopy frequency, and intraoperative blood loss, with a statistically significant difference (P<0.01). Conclusion: The locating device can assist doctors in quickly locating the entry point of intramedullary nail, effectively reducing the fluoroscopy frequency and surgical time by improving the success rate of the guide wire insertion with one shot, improving surgical efficiency, and possessing certain clinical value.


Assuntos
Fixação Intramedular de Fraturas , Cirurgia Assistida por Computador , Humanos , Pinos Ortopédicos , Perda Sanguínea Cirúrgica , Fluoroscopia/métodos , Fixação Intramedular de Fraturas/métodos , Cirurgia Assistida por Computador/métodos
2.
Ugeskr Laeger ; 186(14)2024 Apr 01.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38606703

RESUMO

Bronchoscopy has a low risk of complications when diagnosing peripheral lung lesions suspected of malignancy, however the procedures do not always determine a diagnosis. Several modalities have been invented to improve the diagnostic yield, including radial endobronchial ultrasound and electromagnetic navigation, which are currently used by several departments in Denmark. Augmented fluoroscopy, CT-guided bronchoscopy and robotic bronchoscopy are not yet available in Denmark, but may improve the diagnostic work-up, as argued in this review.


Assuntos
Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Broncoscopia/métodos , Fluoroscopia/métodos , Endossonografia/métodos , Pulmão/patologia
3.
J Laparoendosc Adv Surg Tech A ; 34(4): 305-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38573163

RESUMO

Introduction: Percutaneous endoscopic biliary lithectomy (PEBL) can be performed through preexisting drain tracts, offering ductal clearance and definitive management for patients with complicated gallstone disease unable to undergo conventional therapy. The technique has not been widely adopted by general surgeons. Herein, we describe our technique with surgeon-performed PEBL and present initial results. Materials and Methods: A single institutional retrospective review of the electronic medical record was performed for patients who underwent percutaneous choledochoscopy between February 2019 and November 2020. All operations were performed by 1 of 2 board-certified general surgeons with fellowship training in surgical endoscopy. Preoperative, operative, and postoperative variables were analyzed using descriptive statistics. Results: Thirteen patients underwent PEBL. Seventeen total procedures were performed; 4 patients underwent repeat intervention. The diagnoses leading to PEBL were: cholelithiasis (8), choledocholithiasis (4), and recurrent pancreatitis (1). Complete ductal clearance was achieved in 9 patients (69.2%) during the initial procedure. The remaining 4 patients (30.8%) underwent repeat PEBL, at which point complete ductal clearance was then achieved. The percutaneous drain was removed at the time of final procedure in 5 patients (38.5%) or within 5 weeks in the remaining 8 (61.5%). No intraoperative complications occurred, and no pancreatic or biliary postoperative complications or recurrences were noted with a mean follow-up of 279 ± 240 days. Conclusion: Surgeon-performed PEBL is a safe and effective method of achieving biliary ductal clearance. The technique is readily achieved following basic endoscopic and fluoroscopic principles and should be understood by all physicians managing gallstone disease.


Assuntos
Coledocolitíase , Cirurgiões , Humanos , Endoscopia , Fluoroscopia , Ductos Biliares
4.
Agri ; 36(2): 120-122, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38558396

RESUMO

Hip osteoarthritis (OA) is found in approximately 10% of the population and often causes disability and social limitations in elderly patients. Intra-articular injections are among the most frequently applied interventional treatments for the hip joint. Femoral and obturator sensorial nerve blocks have also been reported to be effective for both diagnostic and therapeutic purposes. A single needle insertion was performed for the blockage of the hip joint and sensory branches. For the sensory branch of the femoral nerve, the needle is advanced at nearly a 45-degree angle toward below the anterior inferior iliac spine near the anterolateral edge of the hip joint. For the sensory branch of the obturator nerve, the needle is advanced at nearly an angle of 45 degrees toward the area below the junction of the pubis and ischium. Finally, for joint injection, the same needle was advanced toward the midline of the anterior femoral head-neck junction at a steeper angle, and blocks were applied. Three patients with hip osteoarthritis were injected with this method and well-being was achieved in a 3-month follow-up. We think that blockage of the hip joint and peripheral sensory branches with a single needle insertion is a fast and effective method. However, prospective controlled studies are needed to determine the efficacy and safety of the method.


Assuntos
Osteoartrite do Quadril , Humanos , Idoso , Osteoartrite do Quadril/tratamento farmacológico , Estudos Prospectivos , Articulação do Quadril , Fluoroscopia , Injeções Intra-Articulares/métodos
5.
Rev. esp. cardiol. (Ed. impr.) ; 77(4): 332-341, abr2024. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-232195

RESUMO

Introducción y objetivos: El implante de stent es el tratamiento de elección en niños mayores y adultos con coartación aórtica (CoA). El objetivo fue determinar la incidencia de eventos tardíos después del tratamiento con stent. Métodos: Se analizó una cohorte de pacientes con CoA tratados en el centro entre 1993 y 2018 a los que se siguió periódicamente, incluyendo evaluación mediante tomografía computarizada (TC) y fluoroscopia. Resultados: Se incluyó a 167 pacientes con TC y fluoroscopia: 83 (49,7%) ≤ 12 años y 46 (28%) mujeres. El tiempo medio de seguimiento clínico fue de 17±8 años (rango 4-30) y de 11±7 años hasta la TC/fluoroscopia. Se detectó aneurisma en un 13% y se asoció al stent PALMAZ (OR=3,09; IC95%, 1,11-9,49; p=0,036) y a la longitud del stent (OR=0,94; IC95%, 0,89-0,99; p=0,039). La fractura del stent fue frecuente (34%) pero no asociada a la presencia de aneurisma. Se asoció con edad joven (OR=3,57; IC95%, 1,54-8,33; p=0,003), sexo masculino (OR=4,00; IC95%, 1,51-12,50; p=0,008) e inversamente con el stent PALMAZ (OR=0,29; IC95%, 0,12-0,67; p=0,005). La reintervención fue menor en adultos (10%), principalmente por aneurismas. Los pacientes que recibieron tratamiento cuando tenían 12 años o menos presentaron tasas de reintervención más altas (43%) debido al crecimiento somático. Conclusiones: Se observó una incidencia notable de eventos tardíos a largo plazo en pacientes con CoA tratados mediante stent. La reintervención fue más frecuente en pacientes tratados a edades más jóvenes. Parece aconsejable una vigilancia periódica mediante pruebas de imagen. (AU)


Introduction and objectives: Stent implantation is the preferred treatment in older children and adults with aortic coarctation (CoA). We aimed to determine the incidence of very late events after CoA stenting. Methods: We analyzed a cohort of CoA patients who underwent stent implantation at our center between 1993 and 2018. Patients were periodically followed up in outpatient clinics, including computed tomography (CT) and fluoroscopy assessment. Results: A total of 167 patients with CT and fluoroscopy data were included: 83 (49.7%) were aged ≤ 12 years and 46 (28%) were female. The mean clinical follow-up time was 17±8 (range 4-30) years and the mean time to CT/fluoroscopy was 11±7 years. Aortic aneurysm was present in 13% and was associated with the PALMAZ stent (OR, 3.09; 95%CI, 1.11-9.49; P=.036) and the stented length (OR, 0.94; 95%CI, 0.89-0.99; P=.039). Stent fracture was frequent (34%), but was not related to the presence of aneurysm. Stent fracture was associated with young age (OR, 3.57; 95%CI, 1.54-8.33; P=.003), male sex (OR, 4.00; 95%CI, 1.51-12.5, P=.008) and inversely with the PALMAZ stent (OR, 0.29; 95%CI, 0.12-0.67, P=.005). Reintervention was lower in adults (10%), mainly related to aneurysms. Those treated when aged ≤ 12 years had higher reintervention rates (43%) due to recoarctation somatic growth. Conclusions: This long-term follow-up study of CoA patients treated with stenting revealed a significant incidence of late events. Reintervention rates were higher in patients treated at younger ages. Periodic imaging surveillance appears to be advisable. (AU)


Assuntos
Humanos , Coartação Aórtica , Cardiopatias Congênitas , Aneurisma , Stents , Tomografia Computadorizada por Raios X , Fluoroscopia
6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 398-404, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632057

RESUMO

Objective: To explore the effectiveness of irreducible intertrochanteric femoral fracture in the elderly by treating with folding top technique and right-angle pliers prying and pulling under G-arm X-ray fluoroscopy. Methods: The clinical data of 74 elderly patients with irreducible intertrochanteric femoral fracture admitted between February 2016 and December 2022 and met the selection criteria were retrospectively analyzed. Among them, 38 cases were treated with folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy and intramedullary nailing fixation (study group), and 36 cases were treated with limited open reduction combined with other reduction methods and intramedullary nailing fixation (control group). There was no significant difference in baseline data between the two groups, such as age, gender, cause of injury, affected side and classification of fractures, complicated medical diseases, and time from injury to operation ( P>0.05). The operation time, intraoperative blood loss, hospital stay, fracture reduction time, fracture healing time, and complications of the two groups were recorded and compared. The quality of fracture reduction was evaluated by Baumgaertner et al. and Chang et al. fracture reduction standards. Results: Patients in both groups were followed up 10-14 months, with an average of 12 months. The operation time and intraoperative blood loss in the study group were significantly less than those in the control group ( P<0.05), there was no significant difference in hospital stay between the two groups ( P>0.05). At 2 days after operation, according to the fracture reduction standards of Baumgaertner et al. and CHANG Shimin et al., the quality of fracture reduction in the study group was better than that in the control group, and the fracture reduction time in the study group was shorter than that in the control group, with significant differences ( P<0.05). After operation, the fractures of the two groups all healed, and there was no significant difference in healing time between the two groups ( P>0.05). During the follow-up, there was no complication such as incision infection, internal fixation failure, deep venous thrombosis of lower limbs, intramedullary nail breakage, spiral blade cutting, or hip varus in the two groups, except for 2 cases of coxa vara in the control group. Conclusion: For the irreducible intertrochanteric femoral fracture, using folding top technique combined with right-angle pliers prying and pulling under G-arm X-ray fluoroscopy can obviously shorten the operation time, reduce the intraoperative blood loss, and improve the quality of fracture reduction.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Humanos , Idoso , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Raios X , Resultado do Tratamento , Pinos Ortopédicos , Fraturas do Quadril/cirurgia , Fluoroscopia , Consolidação da Fratura
7.
J. Am. Coll. Cardiol ; 83(13 Suppl. A)Apr. 2024. tab.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1551803

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) has improved catheter ablation procedures, reducing reliance on fluoroscopy. Yet, the efficacy and safety of zero-fluoroscopy (ZF) procedures remain uncertain. METHODS: We conducted a systematic review and meta-analysis comparing ZF ablation procedures guided by ICE vs. conventional techniques regarding efficacy and safety outcomes. PubMed, Cochrane, and embase were searched. A random-effects model was used to calculate risk ratios (RRs), odds ratios (OR) and mean differences (MDs) with 95% confidence intervals (CI). RESULTS: We includedfourteen studies with 1,919 patients of whom 1,023 (58.72%) performed ZF ablation using ICE. We found a significant reduced ablation time (SMD -0.18; 95% CI -0.31;-0.04; p=0.009), procedure time (MD -7.54; 95% CI -14.68;-0.41; p=0.04), fluoroscopic time (MD -2.52; 95% CI -3.20;-1.84; p<0.001) in patients treated with ZF approach compared with NZF approach. However, there was no significant difference between the two groups in acute success rate (RR 1.00; 95% CI 0.99-1.01; p=0.85), long-term success rate (RR 0.99; 95% CI 0.93-1.05; p=0.77) and complications (RR 0.84, 95% CI: 0.48-1.46; p = 0.54). CONCLUSION: Our findings suggest that among patients undergoing arrhythmia ablation, fluoroscopy-free ICE-guided technique reduces procedure time and radiation exposure with comparable short and long-term success rates and complications.


Assuntos
Fluoroscopia
8.
Clin Cardiol ; 47(3): e24250, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38450791

RESUMO

BACKGROUND: Catheter ablation has become one of the main treatment strategies in patients with premature ventricular complexes (PVC). The successful mapping and ablation can be performed with an ablation catheter without additional diagnostic catheters. HYPOTHESIS: We hypothesize that using a single catheter for PVC ablation may decrease complications, procedure time, and fluoroscopy exposure while maintaining comparable success rates. METHODS: Sixty-nine consecutive patients with PVC were treated with a single catheter approach compared to a historical cohort, in which a conventional setup was used. Propensity score matching was conducted with a 1:1 ratio. Outcome parameters included acute procedural success with elimination of all premature ventricular contractions after catheter ablation, procedural data as well as complication rates. RESULTS: Patients treated with a single catheter approach had shorter total procedure (60 minutes [IQR: 47,5-69,0 minutes] vs. 90 minutes [IQR 60-120 minutes]; p = 0.001) and fluoroscopy times (218 seconds [IQR: 110,5-446 seconds] vs. 310 seconds [IQR 190-640 seconds]; p = 0.012), which consecutively leads to a reduction of radiation exposure signified by a lower dose area product (155 cGycm² [IQR 74.4-334.5 cGycm²] vs. 368.4 cGycm² [IQR: 126-905.4 cGycm²]; p value 0.009). Acute procedural success rates were comparable in both groups (54 [84.3%] in the single catheter approach group and 58 [90.6%] in the conventional group; p: 0.287). CONCLUSION: A single catheter approach for the treatment of PVC is associated with a reduction of procedure- and fluoroscopy time, as well as a lesser radiation exposure, while maintaining equivalent acute success and complication rates compared with a conventionally used catheter setup.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos , Cateteres , Fluoroscopia , Pontuação de Propensão
9.
J Orthop Surg Res ; 19(1): 185, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38491520

RESUMO

INTRODUCTION: When needed operative treatment of sacral fractures is mostly performed with percutaneous iliosacral screw fixation. The advantage of navigation in insertion of pedicle screws already could be shown by former investigations. The aim of this investigation was now to analyze which influence iliosacral screw placement guided by navigation has on duration of surgery, radiation exposure and accuracy of screw placement compared to the technique guided by fluoroscopy. METHODS: 68 Consecutive patients with sacral fractures who have been treated by iliosacral screws were inclouded. Overall, 85 screws have been implanted in these patients. Beside of demographic data the duration of surgery, duration of radiation, dose of radiation and accuracy of screw placement were analyzed. RESULTS: When iliosacral screw placement was guided by navigation instead of fluoroscopy the dose of radiation per inserted screw (155.0 cGy*cm2 vs. 469.4 cGy*cm2 p < 0.0001) as well as the duration of radiation use (84.8 s vs. 147.5 s p < 0.0001) were significantly lower. The use of navigation lead to a significant reduction of duration of surgery (39.0 min vs. 60.1 min p < 0.01). The placement of the screws showed a significantly higher accuracy when performed by navigation (0 misplaced screws vs 6 misplaced screws-p < 0.0001). CONCLUSION: Based on these results minimal invasive iliosacral screw placement guided by navigation seems to be a safe procedure, which leads to a reduced exposure to radiation for the patient and the surgeon, a reduced duration of surgery as well as a higher accuracy of screw placement.


Assuntos
Fraturas Ósseas , Parafusos Pediculares , Fraturas da Coluna Vertebral , Cirurgia Assistida por Computador , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Ílio/lesões , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Cirurgia Assistida por Computador/métodos , Fixação Interna de Fraturas/métodos , Fluoroscopia/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia
10.
J Robot Surg ; 18(1): 121, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492043

RESUMO

The efficacy and safety of robotic-assisted pedicle screw placement compared to traditional fluoroscopy-guided techniques are of great interest in the field of spinal surgery. This systematic review and meta-analysis aimed to compare the outcomes of these two methods in patients with spinal diseases. Following the PRISMA guidelines, we conducted a systematic search across PubMed, Embase, Web of Science, and Cochrane Library. We included randomized controlled trials comparing robotic-assisted and fluoroscopy-guided pedicle screw placement in patients with spinal diseases. Outcome measures included the accuracy of pedicle screw placement, postoperative complication rates, intraoperative radiation exposure time, and duration of surgery. Data were analyzed using Stata software. Our analysis included 12 studies. It revealed significantly higher accuracy in pedicle screw placement with robotic assistance (odds ratio [OR] = 2.83, 95% confidence interval [CI] = 2.20-3.64, P < 0.01). Postoperative complication rates, intraoperative radiation exposure time, and duration of surgery were similar between the two techniques (OR = 0.72, 95% CI = 0.31 to 1.68, P = 0.56 for complication rates; weighted mean difference [WMD] = - 0.13, 95% CI = - 0.93 to 0.68, P = 0.86 for radiation exposure time; WMD = 0.30, 95% CI = - 0.06 to 0.66, P = 0.06 for duration of surgery). Robotic-assisted pedicle screw placement offers superior placement accuracy compared to fluoroscopy-guided techniques. Postoperative complication rates, intraoperative radiation exposure time, and duration of surgery were comparable for both methods. Future studies should explore the potential for fewer complications with the robotic-assisted approach as suggested by the lower point estimate.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Doenças da Coluna Vertebral , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/métodos , Doenças da Coluna Vertebral/etiologia , Fluoroscopia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Cirurgia Assistida por Computador/métodos , Vértebras Lombares/cirurgia
11.
J Orthop Surg (Hong Kong) ; 32(1): 10225536241243166, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38546214

RESUMO

Background: Over the last few decades, shoulder surgery has undergone rapid advancements, with ongoing exploration and the development of innovative technological approaches. In the coming years, technologies such as robot-assisted surgeries, virtual reality, artificial intelligence, patient-specific instrumentation, and different innovative perioperative and preoperative planning tools will continue to fuel a revolution in the medical field, thereby pushing it toward new frontiers and unprecedented advancements. In relation to this, shoulder surgery will experience significant breakthroughs. Main body: Recent advancements and technological innovations in the field were comprehensively analyzed. We aimed to provide a detailed overview of the current landscape, emphasizing the roles of technologies. Computer-assisted surgery utilizing robotic- or image-guided technologies is widely adopted in various orthopedic specialties. The most advanced components of computer-assisted surgery are navigation and robotic systems, with functions and applications that are continuously expanding. Surgical navigation requires a visual system that presents real-time positional data on surgical instruments or implants in relation to the target bone, displayed on a computer monitor. There are three primary categories of surgical planning that utilize navigation systems. The initial category involves volumetric images, such as ultrasound echogram, computed tomography, and magnetic resonance images. The second type is based on intraoperative fluoroscopic images, and the third type incorporates kinetic information about joints or morphometric data about the target bones acquired intraoperatively. Conclusion: The rapid integration of artificial intelligence and deep learning into the medical domain has a significant and transformative influence. Numerous studies utilizing deep learning-based diagnostics in orthopedics have remarkable achievements and performance.


Assuntos
Robótica , Cirurgia Assistida por Computador , Humanos , Inteligência Artificial , Ombro , Fluoroscopia
13.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475148

RESUMO

Ensuring precise angle measurement during surgical correction of orientation-related deformities is crucial for optimal postoperative outcomes, yet there is a lack of an ideal commercial solution. Current measurement sensors and instrumentation have limitations that make their use context-specific, demanding a methodical evaluation of the field. A systematic review was carried out in March 2023. Studies reporting technologies and validation methods for intraoperative angular measurement of anatomical structures were analyzed. A total of 32 studies were included, 17 focused on image-based technologies (6 fluoroscopy, 4 camera-based tracking, and 7 CT-based), while 15 explored non-image-based technologies (6 manual instruments and 9 inertial sensor-based instruments). Image-based technologies offer better accuracy and 3D capabilities but pose challenges like additional equipment, increased radiation exposure, time, and cost. Non-image-based technologies are cost-effective but may be influenced by the surgeon's perception and require careful calibration. Nevertheless, the choice of the proper technology should take into consideration the influence of the expected error in the surgery, surgery type, and radiation dose limit. This comprehensive review serves as a valuable guide for surgeons seeking precise angle measurements intraoperatively. It not only explores the performance and application of existing technologies but also aids in the future development of innovative solutions.


Assuntos
Cirurgia Assistida por Computador , Cirurgia Assistida por Computador/métodos , Fluoroscopia/métodos
14.
Arq Gastroenterol ; 61: e23092, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38511792

RESUMO

BACKGROUND: People recurrently have difficulties swallowing solid medications, which can be associated with the size of the medication and the age and gender of individuals. OBJECTIVE: To evaluate the impact of capsule size and adults' age and gender on oral and pharyngeal capsule transit during capsule swallows. METHODS: Videofluoroscopy was used to measure capsule oral and pharyngeal transit during swallows in 49 healthy individuals (17 men and 32 women), with a mean age of 46 years (ranging from 23 to 88 years). Smaller capsules were filled with 0.50 mL of barium sulfate, and larger capsules were filled with 0.95 mL of barium sulfate; the volume of liquid ingested with the capsules was also quantified in each ingestion. The measurements included the oral preparation time, oral transit time, swallowing reaction time, time to laryngeal vestibule closure, laryngeal vestibule closure duration, pharyngeal transit time, and upper esophageal sphincter opening duration. RESULTS: The capsule size did not influence either the oral or pharyngeal transit time. Increased liquid volume was ingested with larger capsules and by people older than 40 years. The oral transit time was shorter in older adults (60-88 years), and the time to laryngeal vestibule closure was longer in women. CONCLUSION: The size of large capsules did not make a difference in oral or pharyngeal transit when compared with smaller capsules. The capsule size and the participant's age influenced the volume of liquid ingested - larger capsules and older individuals required a larger volume. The capsule oral transit was faster in individuals older than 60 years. BACKGROUND: •Swallowing is influenced by the characteristics of what is being swallowed. BACKGROUND: •There was no difference in swallowing capsules containing 0.50 mL or 0.95 mL. BACKGROUND: •Larger capsules need more liquid ingestion to make swallowing easier. BACKGROUND: •Individuals older than 40 years need a greater volume of liquid to swallow capsules than younger adults.


Assuntos
Transtornos de Deglutição , Laringe , Masculino , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Deglutição , Sulfato de Bário , Transtornos de Deglutição/diagnóstico por imagem , Faringe/diagnóstico por imagem , Fluoroscopia
15.
J Long Term Eff Med Implants ; 34(3): 23-26, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505890

RESUMO

Schatzker III tibial plateau fractures (TPF) reduction and stabilization still represents a challenging procedure. We present an alternative, percutaneous surgical technique. With an antero-medial transverse incision at the level of the tibial metaphysis, under fluoroscopic control, an osteotome is advanced from medial to lateral, under the depressed fragments, reducing the articular surface of the lateral TP anatomically, without creating a significant void and preserving the lateral wall. Final fixation is achieved with screws placed from lateral to medial in a percutaneous fashion, parallel to the articular surface to hold fragments in a rafting way. Open surgical techniques hide many pitfalls and several new reduction options have been described; some simple but invasive, using bone tamps and bone graft that increase surgical trauma; others reliable and safe, but demanding and difficult to reproduce, needing good arthroscopic skills or special and expensive instrumentation, therefore not always available in the operating theater. We prefer a medially based percutaneous metaphyseal bone access using two simple flat low profile instruments such as osteotomes, that preserve bone and vascularization during the reduction maneuvers, minimizing the above-mentioned risks, for the treatment of Schatzker type III TPF.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Fixação Interna de Fraturas , Fluoroscopia , Fraturas da Tíbia/cirurgia , Transplante Ósseo
16.
PLoS One ; 19(3): e0299273, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38452128

RESUMO

PURPOSE: This study aims to evaluate the efficacy and satisfaction of using a multi-angle laser device (MLD) for C-arm fluoroscopy to assist novice learners during lumbar spine surgery. METHODS: Forty novice learners were randomly assigned to Group A using an MLD-equipped C-arm or Group B using a traditional C-arm. Both groups performed X-ray fluoroscopy on a lumbar spine model in supine and rotated positions. Time, number of shots, and deviation from the target were compared. A questionnaire was used to assess the learning experience. RESULTS: Group A required less time (13.66 vs. 25.63 min), and fewer shots (15.05 vs. 32.50), and had a smaller deviation (22.9% vs. 61.5%) than Group B (all p<0.05). The questionnaire revealed higher scores in Group A for comfort, efficiency, and knowledge mastery (all p<0.05). CONCLUSION: The MLD significantly improves novice learning of C-arm fluoroscopy during lumbar spine surgery.


Assuntos
Vértebras Lombares , Cirurgia Assistida por Computador , Fluoroscopia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Inquéritos e Questionários , Humanos
17.
Sci Rep ; 14(1): 6173, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486010

RESUMO

A kidney stone is a solid formation that can lead to kidney failure, severe pain, and reduced quality of life from urinary system blockages. While medical experts can interpret kidney-ureter-bladder (KUB) X-ray images, specific images pose challenges for human detection, requiring significant analysis time. Consequently, developing a detection system becomes crucial for accurately classifying KUB X-ray images. This article applies a transfer learning (TL) model with a pre-trained VGG16 empowered with explainable artificial intelligence (XAI) to establish a system that takes KUB X-ray images and accurately categorizes them as kidney stones or normal cases. The findings demonstrate that the model achieves a testing accuracy of 97.41% in identifying kidney stones or normal KUB X-rays in the dataset used. VGG16 model delivers highly accurate predictions but lacks fairness and explainability in their decision-making process. This study incorporates the Layer-Wise Relevance Propagation (LRP) technique, an explainable artificial intelligence (XAI) technique, to enhance the transparency and effectiveness of the model to address this concern. The XAI technique, specifically LRP, increases the model's fairness and transparency, facilitating human comprehension of the predictions. Consequently, XAI can play an important role in assisting doctors with the accurate identification of kidney stones, thereby facilitating the execution of effective treatment strategies.


Assuntos
Inteligência Artificial , Cálculos Renais , Humanos , Raios X , Qualidade de Vida , Cálculos Renais/diagnóstico por imagem , Fluoroscopia
18.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488065

RESUMO

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Ecocardiografia Transesofagiana , Fluoroscopia , Resultado do Tratamento
19.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
20.
J Bras Pneumol ; 50(1): e20230290, 2024.
Artigo em Inglês, Português | MEDLINE | ID: mdl-38536983

RESUMO

OBJECTIVE: To evaluate the combined impact of videofluoroscopic swallow study (VFSS) and therapeutic feeding and swallowing interventions on clinical outcomes in children with oropharyngeal dysphagia (OPD). METHODS: This was an uncontrolled longitudinal analytical study in which OPD patients were evaluated before and after VFSS. Children ≤ 24 months of age diagnosed with OPD in a clinical setting and undergoing VFSS for investigation and management of OPD were included in the study. The study participants received therapeutic feeding and swallowing interventions after having undergone VFSS, being followed at an outpatient clinic for pediatric dysphagia in order to monitor feeding and swallowing difficulties. Respiratory and feeding outcomes were compared before and after VFSS. RESULTS: Penetration/aspiration events were observed in 61% of the VFSSs (n = 72), and therapeutic feeding and swallowing interventions were recommended for 97% of the study participants. After the VFSS, there was a reduction in the odds of receiving antibiotic therapy (OR = 0.007) and in the duration of antibiotic therapy (p = 0.014), as well as in the odds of being admitted to hospital (p = 0.024) and in the length of hospital stay (p = 0.025). A combination of oral and enteral feeding became more common than oral or enteral feeding alone (p = 0.002). CONCLUSIONS: A high proportion of participants exhibited penetration/aspiration on VFSS. Therapeutic feeding and swallowing interventions following a VFSS appear to be associated with reduced respiratory morbidity in this population.


Assuntos
Transtornos de Deglutição , Deglutição , Humanos , Criança , Transtornos de Deglutição/diagnóstico por imagem , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/terapia , Fluoroscopia , Aspiração Respiratória/etiologia , Aspiração Respiratória/complicações , Antibacterianos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...